Measuring level in wastewater treatment effluent flume
SITRANS Probe LU
Sustainability
A local Siemens representative was visiting a construction site for a new water/ wastewater treatment plant in the Southeast United States. Recent growth in the local housing market near an EPA wetlands area required the installation of a new package treatment plant. Discharge permits for this new plant would require continuous flow monitoring and strict discharge levels for chlorine residual. The accuracy and reliability of the level/flow measurement and chemical feed control system was critical. The discharge flume from the wastewater treatment plant would be approximately 14 meters from the wetlands buffer zone.
The representative recommended using the SITRANS Probe LU transmitter as the primary level device for a Parshall flume at the plant effluent. This level measurement would be sent to a chart recorder which would re-transmit the calculated flow measurement to the metering pump’s flow-proportional controller. The flowproportional controller would receive the flow signal and transmit a dosing signal to the hypochlorite metering pump. The Siemens Probe LU was a logical choice for this critical application. The client was familiar with the accuracy and reliability of the instrument because of their experience with the product at many of their other sites. The Probe LU became the key component of the hypochlorite dosing system. The client’s confidence in Siemens products provided the opportunity for the representative to provide a turnkey solution for the entire hypochlorite system. Siemens track record of success and the support provided through the local representative was critical to the customer’s decision.
• Sales and support when and where you need it Sales and support are available in your area. Our extensive global network means you get sales and support when and where you need it. By using a single supplier with local support, the customer was able to have the equipment installed and Measuring level in wastewater treatment effluent flume siemens.com/level calibrated, as well as have their operators trained on a complete flow measurement and automatically controlled chemical feed system • More dependable measurement The non-contacting ultrasonic transducer is immune to problems caused by suspended solids, harsh corrosives, grease, or silt in the effluent, making the measurement more dependable • Ease of use Simple setup and programming with handheld infrared programmer or via PC software  • Reliable performance from Sonic Intelligence Field proven echo-processing algorithms guarantee the most reliable performance available.